As the professional manufacture, we would like to provide you Super Miniature High Sensitive Signal Relay. In recently years, the factory has won the sincere love of customers by relying on its sincere reputation, professional and and enthusiastic service to convey the three excellent standard services of high quality materials, preferential prices and excellent service to our customers.
● High sensitivity : 0.15W nominal power consumption ● Small size light weight ● Fully sealed construction ● RoHS CompliantAs a professional high quality Super Miniature High Sensitive Signal Relay, you can rest assured to buy Super Miniature High Sensitive Signal Relay from our factory and we will offer you the best after-sale service and timely delivery. Continuous satisfaction of the needs of consumers is the basis for the survival of an enterprise, and products quality is the life of an enterprise.
Low coil power consumption.
High sensitivity.
Small size, light weight.
PC board mounting.
Suitable for automation facilities, telecommunication equipment, wireless radio remote control, sound control toys application etc.
1 Part number JRC-23F
2 Coil power NIL:0.2W H:0.15W
3 Enclosure S: Wash tight NIL: Flux proof
4 Coil rated voltage(V) DC:1.5,3,5,6,9,12,24
Contact Arrangement | 1C(SPDT(B-M) | |
Contact Material | AgNi Au plated) | |
Contact Rating (Resistive) | 0.5A/125VAC; 1A/30VDC; 0.3A/60VDC | |
Max. Switching Power |
30W 62.5VA |
|
Max. Switching Voltage |
60VDC 125VAC Max. Switching Current: 1A |
|
Contact Resistance |
≤100mΩ Item 4.12 of IEC 61810-7 |
|
Operation Life | Electrical |
1×105 Item 4.30 of IEC 61810-7 |
Mechanical |
5×106 Item 4.31 of IEC 61810-7 |
CAUTION:
The min. switching current and min. switching voltage is 50mA/6VDC.
Dash numbers | Coil voltage VDC |
Coil resistance Ω ± 10% |
Pick-up voltage VDC(max) (75%of rated voltage ) | Drop-out voltage VDC(min) (10% of rated voltage) | Coil power W | Operate time ms | Release time ms | |
Rated | Max. | |||||||
001-150 | 1.5 | 3.0 | 15.0 | 1.2 | 0.15 | 0.15 | ≤5 | ≤5 |
003-150 | 3 | 6.0 | 60.0 | 2.4 | 0.30 | |||
005-150 | 5 | 10.0 | 166.7 | 4.0 | 0.50 | |||
006-150 | 6 | 12.0 | 240.0 | 4.8 | 0.60 | |||
009-150 | 9 | 18.0 | 540.0 | 7.2 | 0.90 | |||
012-150 | 12 | 24.0 | 960.0 | 9.6 | 1.20 | |||
024-150 | 24 | 48.0 | 3840.0 | 19.2 | 2.40 | |||
001-200 | 1.5 | 8.7 | 11.3 | 1.2 | 0.15 | 0.2 | ≤5 | ≤5 |
003-200 | 3 | 13.0 | 45.0 | 2.4 | 0.30 | |||
005-200 | 5 | 14.5 | 125.0 | 4.0 | 0.50 | |||
006-200 | 6 | 17.4 | 180.0 | 4.8 | 0.60 | |||
009-200 | 9 | 26.1 | 405.0 | 7.2 | 0.90 | |||
012-200 | 12 | 34.8 | 720.0 | 9.6 | 1.20 | |||
024-200 | 24 | 57.6 | 2880.0 | 19.2 | 2.40 |
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
3.Unless otherwise stated, the rated coil voltage specified in coil parameter table shall be used for all tests and its application to the relay.
Insulation Resistance | 1000M Ω min(at 500VDC) | Item 4.11 of IEC 60255-5 |
Dielectric Strength | ||
Between Contacts | 50Hz 400V | Item 4.7 of IEC 61810-7 |
Between Contact and Coil | 50Hz 1000V | Item 4.7 of IEC 61810-7 |
Shock Resistance | 98m/s² 11ms | Item 4.26 of IEC 61810-7 |
Vibration Resistance | 10Hz~55Hz Double amplitude 3.3mm | Item 4.28 of IEC 61810-7 |
Terminals Strength | 5N | Item 4.24 of IEC 61810-7 |
Temperature Range | -30℃~70℃ | |
Relative Humidity | 5% to 85% | Item 4.16 of IEC 61810-7 |
Mass | 2.2g | Item 4.7 of IEC 61810-7 |
Safety approval | UL&CUR |
Load | 1A/30VDC; 0.5A/125VAC; 0.3A/60VDC |
CAUTION:
In case of no tolerance shown in outline dimension: outline dimension ≤1mm tolerance should be ±0.2mm outline dimension >1mm and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
Address
NO.11, 125 Lane, Qi-Wen Road, Haishu District, Ningbo, Zhejiang, China, 315012
Tel
TradeManager
Skype
VKontakte