As the professional manufacture, we would like to provide you 100A High Power Latching Relay. The company has always been oriented by customer demand and respect for talents, constantly improve their strength, improve service level and quality.
● 100A switching capability ● Single coil and double coils available ● Breaking under 2000A for 0.3ms for 300 times ● Energy Saving ● Environmental friendly productYou can rest assured to buy 100A High Power Latching Relay from our factory and we will offer you the best after-sale service and timely delivery.
Latching relay.
100A contact switching capability.
Max. Inrush current of 500A/2ms.
DC load capability of 100A/60VDC.
Electrical endurance capability: breaking under 2000A for 0.3ms for 3
1 Part number: NT96L
2 Contact arrangement: A:1A;C:1C;
3 Coil: Nil:Single coil; D:Double coils
4 Enclosure: Z: Flux proof; S: Wash tight
5 Polarity: Nil: Standard; R: Reverse polarity
6 Type of load: Nil: AC rating; L:DC rating
7 Contact gap: Nil: Standard; S:1.5mm¹
8 Coil rated voltage(V): DC: 6,9,12,24,48
1) 1.5mm contact gap only applies to A type.
Contact Arrangement | 1A(SPSTNO) 1C(SPDT(B-M)) | ||||
Contact Material | AgSnO₂ | ||||
Contact Rating | 1A | 1C | |||
/277VAC:1×104 | 70A/277VAC:3×10⁴ | ||||
3 0A2 |
VDC:1×104 7VAC:3×10⁴ VAC(Standard VAC(Electronic |
rating):3×10⁴ ballast):3×10⁴ |
|||
Max.Switching Power | 6000W 30800VA | ||||
Max.Switching Voltage | 440VAC Max.Switching Current:100A | ||||
Contact Resistance | ≤10mΩ(1A/24VDC) Item 4.12 of IEC61810-7 | ||||
Operational Life |
Electrical | Refer to the table for the rating details ltem 4.30 of IEC61810-7 | |||
Mechanical | 1×10⁶ Item 4.31 of IEC61810-7 |
Dash numbers |
Rated voltage VDC |
Coil resistance Q±10% |
Set/Reset voltage VDC (80%of rated voltage) |
Pulse duration ms |
Coil power W |
Set time ms |
Reset time ms |
1 Coil |
|||||||
006-3000 009-3000 012-3000 024-3000 048-3000 |
6 9 12 24 48 |
12 27 48 192 768 |
4.8 7.2 9.6 19.2 38.4 |
≥50 |
3 |
≤15 |
≤15 |
2 Coils |
|||||||
006-6000 009-6000 012-6000 024-6000 048-6000 |
6 9 12 24 48 |
2×6 2×13.5 2X24 2X96 2×384 |
4.8 7.2 9.6 19.2 38.4 |
≥50 |
2×6 |
≤15 |
≤15 |
1.When latching relays are installed in equipment, the latch and reset coil should not be powered simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to in be the magnetically neutral position .
2.The above set voltage, reset voltage are the test value for relay without load. Please use 1~1.5 times of rated voltage to drlve the the relay for your application
Insulation Resistance | 1000MQ min (at 500VDC) | tem 4.11 of IEC61810-7 |
Dielectric Strength Between Contacts Between Contact and Coil |
50Hz 1500V 50Hz 4000V |
tem 4.9 of IEC61810-7 tem 4.9 of IEC61810-7 |
Creepage Distance | 8mm | |
Shock Resistance | Functional:98m/s²11ms | tem 4.26 of IEC61810-7 |
Destructive:980m/s²11ms | ||
Vibration Resistance | 10Hz~55Hz Double amplitude 1.5mm | tem 4.28 of IEC61810-7 |
Ambient Temperature | -40℃~70℃ | |
Relative Humidity | 5%to 85% | tem 4.16 of IEC61810-7 |
Mass | 40g | Item 4.7 of IEC61810-7 |
In case of no tolerance shown in outline dimension: outline dimension ≤1mm,tolerance should be±0.2mm ;outline dimension >1mm and ≤5mm, tolerance should be±0.3mm; outline dimension >5mm, tolerance should be±0.4mm.
Address
NO.11, 125 Lane, Qi-Wen Road, Haishu District, Ningbo, Zhejiang, China, 315012
Tel
TradeManager