You are welcomed to come to our factory to buy the latest selling, low price, and high-quality 16A High Sensitivity Latching Relay. We look forward to cooperating with you.
● 20A switching capability ● Product in accordance to IEC60335-1 available ● Low height ● RoHS CompliantYou can rest assured to buy customized 16A High Sensitivity Latching Relay from us. We look forward to cooperating with you, if you want to know more, you can consult us now, we will reply to you in time!
Latching relay.
Small size, light weight and low coil power consumption.
Dielectric strength (between contact and coil): 5kV.
The parts are EN60669-1 standard compliance.
The parts with IEC 60335-1 standard is available.
Contact switching capacity is 20A.
PC board mounting.
1 Part number: NT75L
2 Contact arrangement: A:1A; C:1C
3 Enclosure: S: Wash tight Z: Flux proof
4 Coil: NIL:Single coil D: double coils
5 Polarity Nil: Standard R: Reverse polarity
6 Contact plating: NIL:Standard G:Gold plated
7 Resist heat class F:155℃
8 Coil rated voltage(V): DC:3,5,6,9,12,24
Contact Arrangement | 1A(SPSTNO) 1C(SPDT(B-M)) | |||
Contact Material | AgSnO2 | |||
Contact Rating (Resistive) |
16A/250VAC Motor Load:1HP 240VAC Incandescent Lamp 1500W 277VAC TV-5 120VAC(1A) |
|||
Max. Switching Power | 4000VA | |||
Max. Switching Voltage | 440VAC | Max. Switching Current :20A | ||
Contact Resistance | ≤50mΩ | Item 4.12 of IEC 61810-7 | ||
Operation | Electrical | 5×104 (NO:16A/250VAC 85V℃) | Item 4.30 of IEC 61810-7 | |
Life | Mechanical | 2×106 | Item 4.31 of IEC 61810-7 |
Dash numbers | Rated voltage VDC |
Coil resistance Ω±10% |
Set/Reset voltage VDC (70% of rated voltage ) |
Pulse duration ms | Coil power W | Set time ms | Reset time ms |
1 Coil | |||||||
003-400 | 3 | 22.5 | 2.1 | ≥30 | 0.4 | ≤10 | ≤10 |
005-400 | 5 | 62.5 | 3.5 | ||||
006-400 | 6 | 90 | 4.2 | ||||
009-400 | 9 | 202.5 | 6.3 | ||||
012-400 | 12 | 360 | 8.4 | ||||
024-400 | 24 | 1440 | 16.8 | ||||
2 Coils | |||||||
003-600 | 3 | 2×15 | 2.1 | ≥30 | 2×0.6 | ≤10 | ≤10 |
005-600 | 5 | 2×42 | 3.5 | ||||
006-600 | 6 | 2×60 | 4.2 | ||||
009-600 | 9 | 2×135 | 6.3 | ||||
012-600 | 12 | 2×240 | 8.4 | ||||
024-600 | 24 | 2×960 | 16.8 |
CAUTION:
1. When latching relays are installed in equipment, the latch and reset coil should not be powered simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to in be the magnetically neutral position .
2. Switching voltage is for test purpose only and are no to be used as design criteria.
Insulation Resistance | 1000MΩ min (at 500VDC) | Item 4.11 of IEC 61810-7 |
Dielectric Strength |
|
|
Between Contacts | 50Hz 1000VAC | Item 4.9 of IEC 61810-7 |
Between Contact and Coil | 50Hz 5000VAC | Item 4.9 of IEC 61810-7 |
Creepage Distance | 8.4mm | |
Shock Resistance | Functional: 98m/s² 11ms | Item 4.26 of IEC 61810-7 |
Destructive: 980m/s² 11ms | ||
Vibration Resistance | 10Hz~150Hz 10g/5g | Item 4.28 of IEC 61810-7 |
Terminals Strength | 10N | Item 4.24 of IEC 61810-7 |
Ambient Temperature | -40℃~85℃ | |
Relative Humidity | 5% to 85% | Item 4.16 of IEC 61810-7 |
Mass | 13g | Item 4.7 of IEC 61810-7 |
Safety approval | UL&CUR | CQC |
Load | 16A/250VAC | 16A/250VAC |
CAUTION
In case of no tolerance shown in outline dimension: outline dimension ≤1mm tolerance should be ±0.2mm outline dimension >1mm and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
Address
NO.11, 125 Lane, Qi-Wen Road, Haishu District, Ningbo, Zhejiang, China, 315012
Tel
TradeManager
Skype
VKontakte